From 33af27ee7a189b538452fc9adb63e0784324e009 Mon Sep 17 00:00:00 2001
From: liurunyu <lry9898@163.com>
Date: 星期三, 24 七月 2024 10:49:37 +0800
Subject: [PATCH] Merge branch 'master' of http://8.140.179.55:20000/r/pipIrr-SV

---
 pipIrr-platform/pipIrr-global/src/main/resources/mapper/RmAlarmStateLastMapper.xml |  143 +++++++++++++++++++++++++++++++++++++++++++++++
 1 files changed, 143 insertions(+), 0 deletions(-)

diff --git a/pipIrr-platform/pipIrr-global/src/main/resources/mapper/RmAlarmStateLastMapper.xml b/pipIrr-platform/pipIrr-global/src/main/resources/mapper/RmAlarmStateLastMapper.xml
index b24461d..6fb51ff 100644
--- a/pipIrr-platform/pipIrr-global/src/main/resources/mapper/RmAlarmStateLastMapper.xml
+++ b/pipIrr-platform/pipIrr-global/src/main/resources/mapper/RmAlarmStateLastMapper.xml
@@ -331,4 +331,147 @@
       power_type = #{powerType,jdbcType=TINYINT}
     where id = #{id,jdbcType=BIGINT}
   </update>
+  <!--鏍规嵁鎸囧畾鏉′欢鑾峰彇璁板綍鎬绘暟-->
+  <select id="getRecordCount" resultType="java.lang.Long">
+    select count(*)
+    from rm_alarm_state_last rasl
+    Left join pr_intake pint on intake_id = pint.id
+    <where>
+      <if test="alarmState == 1">
+        and (
+        alarm_remain_water = 1
+        or alarm0_water_remain = 1
+        or alarm_exceed_year = 1
+        or alarm_water_meter_fault = 1
+        or alarm_loss = 1
+        or alarm_water_meter_break = 1
+        or alarm_ele_meter_fault = 1
+        or alarm0_money_remain = 1
+        or alarm_inner_door = 1
+        or alarm_outer_door = 1
+        or alarm_ele_miss = 1
+        or alarm_ele_exceed = 1
+        or alarm_ele_low_volt = 1
+        or alarm_battery_volt = 1
+        or alarm_valve = 1
+        )
+      </if>
+      <if test="alarmState == 0">
+        and (
+        alarm_remain_water = 0
+        and alarm0_water_remain = 0
+        and alarm_exceed_year = 0
+        and alarm_water_meter_fault = 0
+        and alarm_loss = 0
+        and alarm_water_meter_break = 0
+        and alarm_ele_meter_fault = 0
+        and alarm0_money_remain = 0
+        and alarm_inner_door = 0
+        and alarm_outer_door = 0
+        and alarm_ele_miss = 0
+        and alarm_ele_exceed = 0
+        and alarm_ele_low_volt = 0
+        and alarm_battery_volt = 0
+        and alarm_valve = 0
+        )
+      </if>
+      <if test="valveState != null">
+        and rasl.valve_state = #{valveState,jdbcType=TINYINT}
+      </if>
+      <if test="intakeName != null">
+        and pint.name = #{intakeName,jdbcType=VARCHAR}
+      </if>
+      <if test="startDt != null">
+        and rasl.dt &gt;= #{startDt,jdbcType=TIMESTAMP}
+      </if>
+      <if test="endDt != null">
+        and rasl.dt &lt;= #{endDt,jdbcType=TIMESTAMP}
+      </if>
+    </where>
+    </select>
+  <!--鏍规嵁鎸囧畾鏉′欢鑾峰彇璁板綍-->
+  <select id="getControllerAlarmStateLast" resultType="com.dy.pipIrrGlobal.voRm.VoControllerAlarmState">
+    select
+    CAST(rasl.controller_id AS char)AS controllerId,
+    CAST(rasl.intake_id AS char)AS intakeId,
+    pint.name as intakeName,
+    rasl.rtu_addr as rtuAddr,
+    rasl.dt as dt,
+    rasl.valve_state as valveState,
+    rasl.alarm_remain_water as alarmRemainWater,
+    rasl.alarm0_water_remain as alarm0WaterRemain,
+    rasl.alarm_exceed_year as alarmExceedYear,
+    rasl.alarm_water_meter_fault as alarmWaterMeterFault,
+    rasl.alarm_loss as alarmLoss,
+    rasl.alarm_water_meter_break as alarmWaterMeterBreak,
+    rasl.alarm_ele_meter_fault as alarmEleMeterFault,
+    rasl.alarm0_money_remain as alarm0MoneyRemain,
+    rasl.alarm_inner_door as alarmInnerDoor,
+    rasl.alarm_outer_door as alarmOuterDoor,
+    rasl.alarm_ele_miss as alarmEleMiss,
+    rasl.alarm_ele_exceed as alarmEleExceed,
+    rasl.alarm_ele_low_volt as alarmEleLowVolt,
+    rasl.state_ic_enable as stateIcEnable,
+    rasl.alarm_battery_volt as alarmBatteryVolt,
+    rasl.alarm_valve as alarmValve,
+    rasl.power_type as powerType
+    from rm_alarm_state_last rasl
+    Left join pr_intake pint on intake_id = pint.id
+    <where>
+      <if test="alarmState == 1">
+        and (
+        alarm_remain_water = 1
+        or alarm0_water_remain = 1
+        or alarm_exceed_year = 1
+        or alarm_water_meter_fault = 1
+        or alarm_loss = 1
+        or alarm_water_meter_break = 1
+        or alarm_ele_meter_fault = 1
+        or alarm0_money_remain = 1
+        or alarm_inner_door = 1
+        or alarm_outer_door = 1
+        or alarm_ele_miss = 1
+        or alarm_ele_exceed = 1
+        or alarm_ele_low_volt = 1
+        or alarm_battery_volt = 1
+        or alarm_valve = 1
+        )
+      </if>
+      <if test="alarmState == 0">
+        and (
+        alarm_remain_water = 0
+        and alarm0_water_remain = 0
+        and alarm_exceed_year = 0
+        and alarm_water_meter_fault = 0
+        and alarm_loss = 0
+        and alarm_water_meter_break = 0
+        and alarm_ele_meter_fault = 0
+        and alarm0_money_remain = 0
+        and alarm_inner_door = 0
+        and alarm_outer_door = 0
+        and alarm_ele_miss = 0
+        and alarm_ele_exceed = 0
+        and alarm_ele_low_volt = 0
+        and alarm_battery_volt = 0
+        and alarm_valve = 0
+        )
+      </if>
+      <if test="valveState != null">
+        and rasl.valve_state = #{valveState,jdbcType=TINYINT}
+      </if>
+      <if test="intakeName != null">
+        and pint.name like CONCAT('%',#{intakeName,jdbcType=VARCHAR},'%')
+      </if>
+      <if test="startDt != null">
+        and rasl.dt &gt;= #{startDt,jdbcType=TIMESTAMP}
+      </if>
+      <if test="endDt != null">
+        and rasl.dt &lt;= #{endDt,jdbcType=TIMESTAMP}
+      </if>
+    </where>
+    ORDER BY rasl.dt DESC
+    <if test="pageCurr != null and pageSize != null">
+      LIMIT ${(pageCurr-1)*pageSize}, ${pageSize}
+    </if>
+  </select>
 </mapper>
\ No newline at end of file

--
Gitblit v1.8.0