pipIrr-platform/pipIrr-global/src/main/resources/mapper/RmAlarmStateLastMapper.xml
@@ -5,23 +5,33 @@
    <!--@mbg.generated-->
    <!--@Table rm_alarm_state_last-->
    <id column="id" jdbcType="BIGINT" property="id" />
    <result column="controllerId" jdbcType="BIGINT" property="controllerid" />
    <result column="intakeId" jdbcType="BIGINT" property="intakeid" />
    <result column="rtuAddr" jdbcType="VARCHAR" property="rtuaddr" />
    <result column="controller_id" jdbcType="BIGINT" property="controllerId" />
    <result column="intake_id" jdbcType="BIGINT" property="intakeId" />
    <result column="rtu_addr" jdbcType="VARCHAR" property="rtuAddr" />
    <result column="dt" jdbcType="TIMESTAMP" property="dt" />
    <result column="rtuDt" jdbcType="TIMESTAMP" property="rtudt" />
    <result column="bateryVolt" jdbcType="TINYINT" property="bateryvolt" />
    <result column="loss" jdbcType="TINYINT" property="loss" />
    <result column="meter" jdbcType="TINYINT" property="meter" />
    <result column="valve" jdbcType="TINYINT" property="valve" />
    <result column="icCard" jdbcType="TINYINT" property="iccard" />
    <result column="working" jdbcType="TINYINT" property="working" />
    <result column="valveState" jdbcType="TINYINT" property="valvestate" />
    <result column="rtu_dt" jdbcType="TIMESTAMP" property="rtuDt" />
    <result column="valve_state" jdbcType="TINYINT" property="valveState" />
    <result column="alarm_remain_water" jdbcType="TINYINT" property="alarmRemainWater" />
    <result column="alarm0_water_remain" jdbcType="TINYINT" property="alarm0WaterRemain" />
    <result column="alarm_exceed_year" jdbcType="TINYINT" property="alarmExceedYear" />
    <result column="alarm_water_meter_fault" jdbcType="TINYINT" property="alarmWaterMeterFault" />
    <result column="alarm_loss" jdbcType="TINYINT" property="alarmLoss" />
    <result column="alarm_water_meter_break" jdbcType="TINYINT" property="alarmWaterMeterBreak" />
    <result column="alarm_ele_meter_fault" jdbcType="TINYINT" property="alarmEleMeterFault" />
    <result column="alarm0_money_remain" jdbcType="TINYINT" property="alarm0MoneyRemain" />
    <result column="alarm_inner_door" jdbcType="TINYINT" property="alarmInnerDoor" />
    <result column="alarm_outer_door" jdbcType="TINYINT" property="alarmOuterDoor" />
    <result column="alarm_ele_miss" jdbcType="TINYINT" property="alarmEleMiss" />
    <result column="alarm_ele_exceed" jdbcType="TINYINT" property="alarmEleExceed" />
    <result column="alarm_ele_low_volt" jdbcType="TINYINT" property="alarmEleLowVolt" />
    <result column="state_ic_enable" jdbcType="TINYINT" property="stateIcEnable" />
  </resultMap>
  <sql id="Base_Column_List">
    <!--@mbg.generated-->
    id, controllerId, intakeId, rtuAddr, dt, rtuDt, bateryVolt, loss, meter, valve, icCard,
    working, valveState
    id, controller_id, intake_id, rtu_addr, dt, rtu_dt, valve_state, alarm_remain_water,
    alarm0_water_remain, alarm_exceed_year, alarm_water_meter_fault, alarm_loss, alarm_water_meter_break,
    alarm_ele_meter_fault, alarm0_money_remain, alarm_inner_door, alarm_outer_door, alarm_ele_miss,
    alarm_ele_exceed, alarm_ele_low_volt, state_ic_enable
  </sql>
  <select id="selectByPrimaryKey" parameterType="java.lang.Long" resultMap="BaseResultMap">
    <!--@mbg.generated-->
@@ -30,15 +40,13 @@
    from rm_alarm_state_last
    where id = #{id,jdbcType=BIGINT}
  </select>
 <select id="selectByRtuAddr" parameterType="java.lang.String" resultMap="BaseResultMap">
  <select id="selectByRtuAddr" parameterType="java.lang.String" resultMap="BaseResultMap">
    <!--@mbg.generated-->
    select
    <include refid="Base_Column_List" />
    from rm_alarm_state_last
    where rtuAddr = #{rtuAddr,jdbcType=VARCHAR}
    where rtu_addr = #{rtuAddr,jdbcType=VARCHAR}
  </select>
  <delete id="deleteByPrimaryKey" parameterType="java.lang.Long">
    <!--@mbg.generated-->
    delete from rm_alarm_state_last
@@ -46,16 +54,22 @@
  </delete>
  <insert id="insert" parameterType="com.dy.pipIrrGlobal.pojoRm.RmAlarmStateLast">
    <!--@mbg.generated-->
    insert into rm_alarm_state_last (id, controllerId, intakeId,
      rtuAddr, dt, rtuDt, bateryVolt,
      loss, meter, valve,
      icCard, working, valveState
      )
    values (#{id,jdbcType=BIGINT}, #{controllerid,jdbcType=BIGINT}, #{intakeid,jdbcType=BIGINT},
      #{rtuaddr,jdbcType=VARCHAR}, #{dt,jdbcType=TIMESTAMP}, #{rtudt,jdbcType=TIMESTAMP}, #{bateryvolt,jdbcType=TINYINT},
      #{loss,jdbcType=TINYINT}, #{meter,jdbcType=TINYINT}, #{valve,jdbcType=TINYINT},
      #{iccard,jdbcType=TINYINT}, #{working,jdbcType=TINYINT}, #{valvestate,jdbcType=TINYINT}
      )
    insert into rm_alarm_state_last (id, controller_id, intake_id,
      rtu_addr, dt, rtu_dt,
      valve_state, alarm_remain_water, alarm0_water_remain,
      alarm_exceed_year, alarm_water_meter_fault,
      alarm_loss, alarm_water_meter_break, alarm_ele_meter_fault,
      alarm0_money_remain, alarm_inner_door, alarm_outer_door,
      alarm_ele_miss, alarm_ele_exceed, alarm_ele_low_volt,
      state_ic_enable)
    values (#{id,jdbcType=BIGINT}, #{controllerId,jdbcType=BIGINT}, #{intakeId,jdbcType=BIGINT},
      #{rtuAddr,jdbcType=VARCHAR}, #{dt,jdbcType=TIMESTAMP}, #{rtuDt,jdbcType=TIMESTAMP},
      #{valveState,jdbcType=TINYINT}, #{alarmRemainWater,jdbcType=TINYINT}, #{alarm0WaterRemain,jdbcType=TINYINT},
      #{alarmExceedYear,jdbcType=TINYINT}, #{alarmWaterMeterFault,jdbcType=TINYINT},
      #{alarmLoss,jdbcType=TINYINT}, #{alarmWaterMeterBreak,jdbcType=TINYINT}, #{alarmEleMeterFault,jdbcType=TINYINT},
      #{alarm0MoneyRemain,jdbcType=TINYINT}, #{alarmInnerDoor,jdbcType=TINYINT}, #{alarmOuterDoor,jdbcType=TINYINT},
      #{alarmEleMiss,jdbcType=TINYINT}, #{alarmEleExceed,jdbcType=TINYINT}, #{alarmEleLowVolt,jdbcType=TINYINT},
      #{stateIcEnable,jdbcType=TINYINT})
  </insert>
  <insert id="insertSelective" parameterType="com.dy.pipIrrGlobal.pojoRm.RmAlarmStateLast">
    <!--@mbg.generated-->
@@ -64,82 +78,130 @@
      <if test="id != null">
        id,
      </if>
      <if test="controllerid != null">
        controllerId,
      <if test="controllerId != null">
        controller_id,
      </if>
      <if test="intakeid != null">
        intakeId,
      <if test="intakeId != null">
        intake_id,
      </if>
      <if test="rtuaddr != null">
        rtuAddr,
      <if test="rtuAddr != null">
        rtu_addr,
      </if>
      <if test="dt != null">
        dt,
      </if>
      <if test="rtudt != null">
        rtuDt,
      <if test="rtuDt != null">
        rtu_dt,
      </if>
      <if test="bateryvolt != null">
        bateryVolt,
      <if test="valveState != null">
        valve_state,
      </if>
      <if test="loss != null">
        loss,
      <if test="alarmRemainWater != null">
        alarm_remain_water,
      </if>
      <if test="meter != null">
        meter,
      <if test="alarm0WaterRemain != null">
        alarm0_water_remain,
      </if>
      <if test="valve != null">
        valve,
      <if test="alarmExceedYear != null">
        alarm_exceed_year,
      </if>
      <if test="iccard != null">
        icCard,
      <if test="alarmWaterMeterFault != null">
        alarm_water_meter_fault,
      </if>
      <if test="working != null">
        working,
      <if test="alarmLoss != null">
        alarm_loss,
      </if>
      <if test="valvestate != null">
        valveState,
      <if test="alarmWaterMeterBreak != null">
        alarm_water_meter_break,
      </if>
      <if test="alarmEleMeterFault != null">
        alarm_ele_meter_fault,
      </if>
      <if test="alarm0MoneyRemain != null">
        alarm0_money_remain,
      </if>
      <if test="alarmInnerDoor != null">
        alarm_inner_door,
      </if>
      <if test="alarmOuterDoor != null">
        alarm_outer_door,
      </if>
      <if test="alarmEleMiss != null">
        alarm_ele_miss,
      </if>
      <if test="alarmEleExceed != null">
        alarm_ele_exceed,
      </if>
      <if test="alarmEleLowVolt != null">
        alarm_ele_low_volt,
      </if>
      <if test="stateIcEnable != null">
        state_ic_enable,
      </if>
    </trim>
    <trim prefix="values (" suffix=")" suffixOverrides=",">
      <if test="id != null">
        #{id,jdbcType=BIGINT},
      </if>
      <if test="controllerid != null">
        #{controllerid,jdbcType=BIGINT},
      <if test="controllerId != null">
        #{controllerId,jdbcType=BIGINT},
      </if>
      <if test="intakeid != null">
        #{intakeid,jdbcType=BIGINT},
      <if test="intakeId != null">
        #{intakeId,jdbcType=BIGINT},
      </if>
      <if test="rtuaddr != null">
        #{rtuaddr,jdbcType=VARCHAR},
      <if test="rtuAddr != null">
        #{rtuAddr,jdbcType=VARCHAR},
      </if>
      <if test="dt != null">
        #{dt,jdbcType=TIMESTAMP},
      </if>
      <if test="rtudt != null">
        #{rtudt,jdbcType=TIMESTAMP},
      <if test="rtuDt != null">
        #{rtuDt,jdbcType=TIMESTAMP},
      </if>
      <if test="bateryvolt != null">
        #{bateryvolt,jdbcType=TINYINT},
      <if test="valveState != null">
        #{valveState,jdbcType=TINYINT},
      </if>
      <if test="loss != null">
        #{loss,jdbcType=TINYINT},
      <if test="alarmRemainWater != null">
        #{alarmRemainWater,jdbcType=TINYINT},
      </if>
      <if test="meter != null">
        #{meter,jdbcType=TINYINT},
      <if test="alarm0WaterRemain != null">
        #{alarm0WaterRemain,jdbcType=TINYINT},
      </if>
      <if test="valve != null">
        #{valve,jdbcType=TINYINT},
      <if test="alarmExceedYear != null">
        #{alarmExceedYear,jdbcType=TINYINT},
      </if>
      <if test="iccard != null">
        #{iccard,jdbcType=TINYINT},
      <if test="alarmWaterMeterFault != null">
        #{alarmWaterMeterFault,jdbcType=TINYINT},
      </if>
      <if test="working != null">
        #{working,jdbcType=TINYINT},
      <if test="alarmLoss != null">
        #{alarmLoss,jdbcType=TINYINT},
      </if>
      <if test="valvestate != null">
        #{valvestate,jdbcType=TINYINT},
      <if test="alarmWaterMeterBreak != null">
        #{alarmWaterMeterBreak,jdbcType=TINYINT},
      </if>
      <if test="alarmEleMeterFault != null">
        #{alarmEleMeterFault,jdbcType=TINYINT},
      </if>
      <if test="alarm0MoneyRemain != null">
        #{alarm0MoneyRemain,jdbcType=TINYINT},
      </if>
      <if test="alarmInnerDoor != null">
        #{alarmInnerDoor,jdbcType=TINYINT},
      </if>
      <if test="alarmOuterDoor != null">
        #{alarmOuterDoor,jdbcType=TINYINT},
      </if>
      <if test="alarmEleMiss != null">
        #{alarmEleMiss,jdbcType=TINYINT},
      </if>
      <if test="alarmEleExceed != null">
        #{alarmEleExceed,jdbcType=TINYINT},
      </if>
      <if test="alarmEleLowVolt != null">
        #{alarmEleLowVolt,jdbcType=TINYINT},
      </if>
      <if test="stateIcEnable != null">
        #{stateIcEnable,jdbcType=TINYINT},
      </if>
    </trim>
  </insert>
@@ -147,41 +209,65 @@
    <!--@mbg.generated-->
    update rm_alarm_state_last
    <set>
      <if test="controllerid != null">
        controllerId = #{controllerid,jdbcType=BIGINT},
      <if test="controllerId != null">
        controller_id = #{controllerId,jdbcType=BIGINT},
      </if>
      <if test="intakeid != null">
        intakeId = #{intakeid,jdbcType=BIGINT},
      <if test="intakeId != null">
        intake_id = #{intakeId,jdbcType=BIGINT},
      </if>
      <if test="rtuaddr != null">
        rtuAddr = #{rtuaddr,jdbcType=VARCHAR},
      <if test="rtuAddr != null">
        rtu_addr = #{rtuAddr,jdbcType=VARCHAR},
      </if>
      <if test="dt != null">
        dt = #{dt,jdbcType=TIMESTAMP},
      </if>
      <if test="rtudt != null">
        rtuDt = #{rtudt,jdbcType=TIMESTAMP},
      <if test="rtuDt != null">
        rtu_dt = #{rtuDt,jdbcType=TIMESTAMP},
      </if>
      <if test="bateryvolt != null">
        bateryVolt = #{bateryvolt,jdbcType=TINYINT},
      <if test="valveState != null">
        valve_state = #{valveState,jdbcType=TINYINT},
      </if>
      <if test="loss != null">
        loss = #{loss,jdbcType=TINYINT},
      <if test="alarmRemainWater != null">
        alarm_remain_water = #{alarmRemainWater,jdbcType=TINYINT},
      </if>
      <if test="meter != null">
        meter = #{meter,jdbcType=TINYINT},
      <if test="alarm0WaterRemain != null">
        alarm0_water_remain = #{alarm0WaterRemain,jdbcType=TINYINT},
      </if>
      <if test="valve != null">
        valve = #{valve,jdbcType=TINYINT},
      <if test="alarmExceedYear != null">
        alarm_exceed_year = #{alarmExceedYear,jdbcType=TINYINT},
      </if>
      <if test="iccard != null">
        icCard = #{iccard,jdbcType=TINYINT},
      <if test="alarmWaterMeterFault != null">
        alarm_water_meter_fault = #{alarmWaterMeterFault,jdbcType=TINYINT},
      </if>
      <if test="working != null">
        working = #{working,jdbcType=TINYINT},
      <if test="alarmLoss != null">
        alarm_loss = #{alarmLoss,jdbcType=TINYINT},
      </if>
      <if test="valvestate != null">
        valveState = #{valvestate,jdbcType=TINYINT},
      <if test="alarmWaterMeterBreak != null">
        alarm_water_meter_break = #{alarmWaterMeterBreak,jdbcType=TINYINT},
      </if>
      <if test="alarmEleMeterFault != null">
        alarm_ele_meter_fault = #{alarmEleMeterFault,jdbcType=TINYINT},
      </if>
      <if test="alarm0MoneyRemain != null">
        alarm0_money_remain = #{alarm0MoneyRemain,jdbcType=TINYINT},
      </if>
      <if test="alarmInnerDoor != null">
        alarm_inner_door = #{alarmInnerDoor,jdbcType=TINYINT},
      </if>
      <if test="alarmOuterDoor != null">
        alarm_outer_door = #{alarmOuterDoor,jdbcType=TINYINT},
      </if>
      <if test="alarmEleMiss != null">
        alarm_ele_miss = #{alarmEleMiss,jdbcType=TINYINT},
      </if>
      <if test="alarmEleExceed != null">
        alarm_ele_exceed = #{alarmEleExceed,jdbcType=TINYINT},
      </if>
      <if test="alarmEleLowVolt != null">
        alarm_ele_low_volt = #{alarmEleLowVolt,jdbcType=TINYINT},
      </if>
      <if test="stateIcEnable != null">
        state_ic_enable = #{stateIcEnable,jdbcType=TINYINT},
      </if>
    </set>
    where id = #{id,jdbcType=BIGINT}
@@ -189,18 +275,26 @@
  <update id="updateByPrimaryKey" parameterType="com.dy.pipIrrGlobal.pojoRm.RmAlarmStateLast">
    <!--@mbg.generated-->
    update rm_alarm_state_last
    set controllerId = #{controllerid,jdbcType=BIGINT},
      intakeId = #{intakeid,jdbcType=BIGINT},
      rtuAddr = #{rtuaddr,jdbcType=VARCHAR},
    set controller_id = #{controllerId,jdbcType=BIGINT},
      intake_id = #{intakeId,jdbcType=BIGINT},
      rtu_addr = #{rtuAddr,jdbcType=VARCHAR},
      dt = #{dt,jdbcType=TIMESTAMP},
      rtuDt = #{rtudt,jdbcType=TIMESTAMP},
      bateryVolt = #{bateryvolt,jdbcType=TINYINT},
      loss = #{loss,jdbcType=TINYINT},
      meter = #{meter,jdbcType=TINYINT},
      valve = #{valve,jdbcType=TINYINT},
      icCard = #{iccard,jdbcType=TINYINT},
      working = #{working,jdbcType=TINYINT},
      valveState = #{valvestate,jdbcType=TINYINT}
      rtu_dt = #{rtuDt,jdbcType=TIMESTAMP},
      valve_state = #{valveState,jdbcType=TINYINT},
      alarm_remain_water = #{alarmRemainWater,jdbcType=TINYINT},
      alarm0_water_remain = #{alarm0WaterRemain,jdbcType=TINYINT},
      alarm_exceed_year = #{alarmExceedYear,jdbcType=TINYINT},
      alarm_water_meter_fault = #{alarmWaterMeterFault,jdbcType=TINYINT},
      alarm_loss = #{alarmLoss,jdbcType=TINYINT},
      alarm_water_meter_break = #{alarmWaterMeterBreak,jdbcType=TINYINT},
      alarm_ele_meter_fault = #{alarmEleMeterFault,jdbcType=TINYINT},
      alarm0_money_remain = #{alarm0MoneyRemain,jdbcType=TINYINT},
      alarm_inner_door = #{alarmInnerDoor,jdbcType=TINYINT},
      alarm_outer_door = #{alarmOuterDoor,jdbcType=TINYINT},
      alarm_ele_miss = #{alarmEleMiss,jdbcType=TINYINT},
      alarm_ele_exceed = #{alarmEleExceed,jdbcType=TINYINT},
      alarm_ele_low_volt = #{alarmEleLowVolt,jdbcType=TINYINT},
      state_ic_enable = #{stateIcEnable,jdbcType=TINYINT}
    where id = #{id,jdbcType=BIGINT}
  </update>
</mapper>