| | | onlyOneProtocol=true: éä¿¡ä¸é´ä»¶å½ååªæä¸ä¸ªåè®® |
| | | downComandMaxResendTimes: ä¸è¡å½ä»¤å
许åéçæå¤§æ¬¡æ°Xï¼å³å
许éåX-1 |
| | | commandSendInterval: é对ä¸ä¸ªRTUï¼ä¸åå½ä»¤çæ¶é´é´é(ç§) |
| | | cachWaitResultTimeout: å½ä»¤å·²ç»åéè¾¾æå¤§æ¬¡æ°ï¼ä»æªæ¶å°å½ä»¤ç»æï¼éè¦å¨ç¼åç»§ç»çå¾
ï¼å
¶çå¾
æå¤§æ¶é¿(ç§)ï¼æ¬ç³»ç»RTUï¼å¯¹äºå¼å
³æ³µå½ä»¤ï¼å
¶å
æ§è¡å¼å
³æ³µæ¥ï¼ç¶ååè¿è¡å½ä»¤åºçï¼æä»¥æ¤å¼ è¦å¤§ä¸äº |
| | | offLineCachTimeout: ä¸å¨çº¿ç¼åçå½ä»¤æå¤§ç¼åæ¶é¿(ç§) |
| | | lastUpDataTimeLive: TCPä¸è¡æ°æ®æ¶å»ç¼åæ¶é¿(毫ç§)ï¼å½è¾¾å°æ¶é¿æ¶ï¼TCPä¸è¡æ°æ®æ¶å»è¢«æ¸
空ï¼éç¨TCPä¸è¡æ°æ®æ¶å»ç®çæ¯ï¼é»æ¢ä¸è¡æ°æ®åæ¶ä¸åæ°æ®ï¼å 为RTUå¤çä¸è¿æ¥(ç»å次å®éªï¼1ç§è¿æ¯æé®é¢ï¼2ç§æ é®é¢) |
| | | fastCommandSendInterval: é对ä¸ä¸ªRTUï¼ä¸åå¿«éå½ä»¤ï¼å¦å级å½ä»¤ï¼çæ¶é´é´é(毫ç§)ï¼æ¤é
ç½®ä½ç¨ååä¸é¢é
置项lastUpDataTimeLiveéå¶ |
| | | cacheWaitResultTimeout: å½ä»¤å·²ç»åéè¾¾æå¤§æ¬¡æ°ï¼ä»æªæ¶å°å½ä»¤ç»æï¼éè¦å¨ç¼åç»§ç»çå¾
ï¼å
¶çå¾
æå¤§æ¶é¿(ç§)ï¼æ¬ç³»ç»RTUï¼å¯¹äºå¼å
³æ³µå½ä»¤ï¼å
¶å
æ§è¡å¼å
³æ³µæ¥ï¼ç¶ååè¿è¡å½ä»¤åºçï¼æä»¥æ¤å¼ è¦å¤§ä¸äº |
| | | offLineCacheTimeout: ä¸å¨çº¿ç¼åçå½ä»¤æå¤§ç¼åæ¶é¿(ç§) |
| | | lastUpDataTimeLive: TCPä¸è¡æ°æ®æ¶å»ç¼åæ¶é¿(毫ç§)ï¼å½è¾¾å°æ¶é¿æ¶ï¼TCPä¸è¡æ°æ®æ¶å»è¢«æ¸
空ï¼éç¨TCPä¸è¡æ°æ®æ¶å»ç®çæ¯ï¼é»æ¢ä¸è¡æ°æ®åæ¶ä¸åæ°æ®ï¼å 为RTUå¤çä¸è¿æ¥ |
| | | dbDataIdSuffixï¼æ°æ®åºæ°æ®idçæå¨çidåç¼ï¼0æ¯é»è®¤çåç¼ï¼ä¸è¬webç³»ç»åºç¨ï¼æ°æ®ä¸é´ä»¶idåç¼å¤§äºçäº1 |
| | | cacheUpDownDataWarnCountï¼ä¸ä¸è¡æ°æ®ç¼åéåä¸ç¼åæ°æ®ä¸ªæ°çæ¥è¦éï¼è¿ä¸ªä¸ç°å®é¡¹ç®ææ¥æ°´è¡¨æ°ç¸å
³ |
| | | cacheUpDownDataMaxCountï¼ä¸ä¸è¡æ°æ®ç¼åéåä¸ç¼åæ°æ®ä¸ªæ°çæå¤§å¼ï¼è¿ä¸ªä¸ç°å®é¡¹ç®ææ¥æ°´è¡¨æ°ç¸å
³ |
| | | disconnectedByNoUpDataMinutesï¼æ²¡æä¸è¡æ°æ®çåéæ°ï¼è¾¾å°è¿ä¸ªåéæ°ï¼è®¤ä¸ºRTUæç½äºï¼åå¼èå´æ¯2-100 |
| | | workReportDealOneByTimes: 工使¥å¤ªé¢ç¹ï¼Næ¬¡ä¸æ¥å¤ç1次ï¼åå¼èå´æ¯1-100 |
| | | intakeAlarmLossMinValue: 触ååéééæ¥è¦æ¶æ¯çåæ°´å£æ¥æ¼æéçæå°å¼ï¼å
æ¬ä½é¤0.0å¤ï¼ï¼å°æ°ï¼ |
| | | sendDingDingAlarmMsInterval: ææ¥è¦åçæ¶ï¼åééåéæ¶æ¯çé´éæ¶é¿ï¼åéï¼ |
| | | --> |
| | | <base |
| | | orgTag="test" |
| | | isLowPower="false" |
| | | onlyDealRtus="" |
| | | onlyOneProtocol="false" |
| | | downComandMaxResendTimes="1" |
| | | commandSendInterval="2" |
| | | cachWaitResultTimeout="120" |
| | | offLineCachTimeout="86400" |
| | | lastUpDataTimeLive="500" |
| | | dbDataIdSuffix="0" |
| | | cacheUpDownDataWarnCount="100000" |
| | | cacheUpDownDataMaxCount="110000" |
| | | disconnectedByNoUpDataMinutes="3" |
| | | workReportDealOneByTimes="5" |
| | | sendDingDingAlarmMsInterval="60" |
| | | orgTag="test" |
| | | isLowPower="false" |
| | | onlyDealRtus="" |
| | | onlyOneProtocol="false" |
| | | downComandMaxResendTimes="1" |
| | | commandSendInterval="3" |
| | | fastCommandSendInterval="500" |
| | | cacheWaitResultTimeout="120" |
| | | offLineCacheTimeout="86400" |
| | | lastUpDataTimeLive="500" |
| | | dbDataIdSuffix="0" |
| | | cacheUpDownDataWarnCount="100000" |
| | | cacheUpDownDataMaxCount="110000" |
| | | disconnectedByNoUpDataMinutes="3" |
| | | workReportDealOneByTimes="5" |
| | | intakeAlarmLossMinValue="1.0" |
| | | sendDingDingAlarmMsInterval="60" |
| | | /> |
| | | |
| | | <!-- |
| | |
| | | synchroRtuClockTimepiecesï¼å½RTU䏿å¡å¨æ¶éç¸å·®ä¸å®æ¯«ç§ï¼é
ç½®æä»¶æ¯ç§éï¼åï¼è¿è¡æ ¡æ¶ |
| | | --> |
| | | <protocol |
| | | centerAddr="1" |
| | | synchroRtuClock="true" |
| | | synchroRtuClockTimepieces="300000" |
| | | centerAddr="1" |
| | | synchroRtuClock="true" |
| | | synchroRtuClockTimepieces="300000" |
| | | /> |
| | | |
| | | <!-- RTU æ¶æ¯ä¸å¿ |
| | | enable: æ¨¡åæ¯å¦å¯å¨ |
| | | notifyInterval: æ¶æ¯éç¥é´éï¼ç§ï¼ |
| | | --> |
| | | <msCenter enable="true" |
| | | notifyInterval="5" |
| | | /> |
| | | |
| | | <!-- 2024-10-08 æ¤é
ç½®ææ¶æªåºç¨ |
| | | 软件å级 --> |
| | | <updateRtuSoft enable="true"> |
| | | <soft1 enable="true" oldVersionName="meter_v2_0,meter_v1_0" > |
| | | <newVersion newVersionName="meter_v3_0" file="rtuSoft/meter_v3_0.txt"></newVersion> |
| | | </soft1> |
| | | <!-- |
| | | <soft2 enable="false" oldVersionName="rtu_v1_0,rtu_v2_0,rtu_v3_0" > |
| | | <newVersion newVersionName="rtu_v4_0" file="rtuSoft/rtu_v4_0.txt"></newVersion> |
| | | </soft2> |
| | | --> |
| | | </updateRtuSoft> |
| | | <!-- RTU 软件å级 |
| | | enable: æ¨¡åæ¯å¦å¯å¨ |
| | | openNoUpgrade: éå¼ï¼æ³µå¼ï¼ä¸æ§è¡å级 |
| | | lastOpenMaxGoOn: éå¼ï¼æ³µå¼ï¼ç¶æè®¾ç½®ä»¥æ¥æç»æé¿æ¶é´ï¼ç§éï¼ï¼è¶
è¿è¿ä¸ªæ¶é´è®¤ä¸ºç¶ææ æï¼è¿ä¸ªæ¶é¿åå³äºå·¥ä½æ¥é´éï¼ |
| | | noOneRtuUpgradeMaxDurationï¼å级任å¡è®¾ç½®åï¼æ ä¸è®¾å¤å级æå¤§æ¶é¿ï¼ç§ï¼ï¼è¶
è¿è¿ä¸ªæ¶é¿ï¼è®¤ä¸ºå级任å¡å®æï¼åå¼èå´æ¯5åé~60åé |
| | | runningAndIdleDurationï¼rtuå级å¯å¨åè¿å
¥å级ä¸ç¶æï¼ä½æç§æ
åµä¸RTUä¸åéä¿¡äºï¼ä¸ç´å¤äºçå¾
ç¶æï¼çå¾
è¾¾å°ä¸å®æ¶é¿ï¼ç§ï¼ä¸è¬ä¸noOneRtuUpgradeMaxDurationç¸çï¼è®¤ä¸ºå级失败ï¼ä¸å
æ»æå¤å
æ»ï¼ï¼åå¼èå´æ¯5åé~60åé |
| | | failTryTimesï¼å级失败åï¼éå¯¹çæ¯å¨çº¿è¿è¡äºå级ä¸åå½ä»¤ï¼ï¼éæ°å¿è¯å级次æ°ï¼å½è®¾ç½®ä¸º0æ¶è¡¨ç¤ºä¸éæ°å¿è¯å级 |
| | | ugMaxRtuAtOnceï¼ä¸ºäºç¼è§£éä¿¡ä¸é´ä»¶çååï¼åæ¶æ¯æå级çRTUå°æ°ï¼å½è®¾ç½®ä¸º0æ¶è¡¨ç¤ºä¸åéå¶ |
| | | rtuOffLineWaitDuration: rtu离线ï¼çå¾
å
¶åçº§çæ¶é¿ï¼ç§ï¼ï¼è¶
è¿è¿ä¸ªæ¶é´ï¼è®¾ç½®å
¶å级失败ï¼ä¸è®¾ç½®å级任å¡å®æ |
| | | notifyStateInterval: åçº§ç¶æéç¥é´éï¼ç§ï¼ |
| | | notifyTimesAfterOver: åçº§ç»æåï¼ååwebæå¡ç³»ç»éç¥ç¶æçæ¬¡æ° |
| | | --> |
| | | <upgrade enable="true" |
| | | openNoUpgrade="true" |
| | | lastOpenMaxGoOn="1800" |
| | | noOneRtuUpgradeMaxDuration="1200" |
| | | runningAndIdleDuration="1200" |
| | | failTryTimes="2" |
| | | ugMaxRtuAtOnce="5000" |
| | | rtuOffLineWaitDuration="1800" |
| | | notifyStateInterval="2" |
| | | notifyTimesAfterOver="1" |
| | | /> |
| | | |
| | | |
| | | <!-- |
| | | æ¯ææ¨¡å |
| | |
| | | enableThreadPoolï¼æ¯å¦å¯ç¨çº¿ç¨æ± |
| | | --> |
| | | <support |
| | | short_maxThread="6" |
| | | short_minThread="6" |
| | | short_freeTimeout="60" |
| | | short_busyTimeout="5" |
| | | long_maxThread="6" |
| | | long_minThread="6" |
| | | long_freeTimeout="60" |
| | | long_busyTimeout="-1" |
| | | enableThreadPool="true" |
| | | short_maxThread="6" |
| | | short_minThread="6" |
| | | short_freeTimeout="60" |
| | | short_busyTimeout="5" |
| | | long_maxThread="6" |
| | | long_minThread="6" |
| | | long_freeTimeout="60" |
| | | long_busyTimeout="-1" |
| | | enableThreadPool="true" |
| | | /> |
| | | |
| | | <!-- |
| | | èµæºæ¨¡å |
| | | rtuLogDirï¼RTUæ¥å¿æä»¶åå¨ç®å½(ç¸å¯¹ç®å½) |
| | | rtuLogFileMaxSizeï¼RTUæ¥å¿æä»¶æå¤§åèæ°(KB) |
| | | rtuLogFileMaxSizeï¼RTUæ¥å¿æä»¶æå¤§åèæ°(B) |
| | | rtuLogFileMaxCountï¼RTUæ¥å¿æä»¶æå¤§æä»¶æ° |
| | | monitorIntervalï¼Rtuç¶æçè§é´é(åé) |
| | | saveDbIntervalï¼Rtuç¶æåæ°æ®åºé´é(åé) |
| | | --> |
| | | <resource |
| | | rtuLogDir="rtuLogs/" |
| | | rtuLogFileMaxSize="1000" |
| | | rtuLogFileMaxCount="2" |
| | | monitorInterval="2" |
| | | saveDbInterval="10" |
| | | rtuLogDir="rtuLogs/" |
| | | rtuLogFileMaxSize="1000000" |
| | | rtuLogFileMaxCount="3" |
| | | monitorInterval="2" |
| | | saveDbInterval="10" |
| | | /> |
| | | |
| | | |
| | |
| | | /> |
| | | |
| | | <!-- |
| | | sleepBigBusyï¼ä¸»çº¿ç¨å¤§å¿æ¶æ¯æ¬¡æ§è¡é´éæ¶é¿ï¼æ¯«ç§ï¼ |
| | | sleepSmallBusyï¼ä¸»çº¿ç¨å°å¿æ¶æ¯æ¬¡æ§è¡é´éæ¶é¿ï¼æ¯«ç§ï¼ |
| | | coreIntervalï¼ä¸»çº¿ç¨æ¯æ¬¡æ§è¡é´éæ¶é¿ï¼æ¯«ç§ï¼ |
| | | queueWarnSize: ç¼åéåèç¹æ°è¦åæ°é |
| | | queueMaxSize: ç¼åéåèç¹æ°æå¤§æ°é |
| | | --> |
| | | <core |
| | | sleepBigBusy="100" |
| | | sleepSmallBusy="500" |
| | | queueWarnSize="100000" |
| | | queueMaxSize="300000" |
| | | coreInterval="100" |
| | | queueWarnSize="100000" |
| | | queueMaxSize="300000" |
| | | /> |
| | | |
| | | <!-- |